SAS and SATA Hard Drive - LED Combinations/behavior Explained
| Online/Activity LED (green) | Fault/UID LED (amber/blue) | Interpretation |
|---|---|---|
| On, off, or flashing | Alternating amber and blue | The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. |
| On, off, or flashing | Steadily blue | The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. |
| On | Amber, flashing regularly (1 Hz) | A predictive failure alert has been received for this drive. Replace the drive as soon as possible. |
| On | Off | The drive is online, but it is not currently active |
| Flashing regularly (1 Hz) | Amber, flashing regularly (1 Hz) | Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. |
| Flashing regularly (1 Hz) | Off | Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration. |
| Flashing irregularly | Amber, flashing regularly (1 Hz) | The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. |
| Flashing irregularly | Off | The drive is active, and it is operating normally. |
| Off | Steadily amber | Steadily amber A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. |
| Off | Amber, flashing regularly (1 Hz) | A predictive failure alert has been received for this drive. Replace the drive as soon as possible |
| Off | Off | The drive is offline, a spare, or not configured as part of an array |
Sunday, May 1, 2011
The Execute Disable/No Execute CPU feature is not enabled for this machine.
The Execute Disable/No Execute CPU feature is not enabled for this machine.
There is No-Execute Memory Protection parameter, which is disabled, under the Processor Options (under Advanced Options) in the BIOS.
Go to the BIOS set up and enable it.
Thursday, April 28, 2011
Recommended BIOS Settings on HP ProLiant DL580 G7 for VMware vSphere
The HP Proliant DL580 G7 has several important BIOS Settings which need to be set.
The default options are in Italic while the non-default (recommended) options are in Bold.
Options which are not relevant are left out.
You might need to change options if you have a specific configuration or specific needs. This list is only a general guideline for most of the settings tuned for vSphere.
Option | Value | Description |
| System Options | ||
| –Serial Port Options | ||
| —-Embedded Serial Port | COM 1; IRQ4; IO: 3F8h-3FFh | The onboard Serial Port is left enabled in case Serial-Line logging at the server is needed. |
| —-Virtual Serial Port | COM 2; IRQ3; IO: 2F8h-2FFh | The Virtual Serial Port is needed to do Serial-Line logging through iLO 3. |
| –Embedded NICs | | |
| —-Embedded NIC Boot Options | Disabled | If you don't PXE boot the server, set it to disabled. Otherwise, leave it enabled. Setting it to disabled saves you 2 seconds when booting the server |
| –Advanced Memory Protection | Advanced ECC Support | Depending on your needs, you might want to select improved Memory Protection |
| –USB Options | | |
| —-USB Control | USB Enabled | Allows the use of Keyboard and Mouse during vSphere setup. |
| —-USB 2.0 Controller | Enabled | Allows USB 2.0 high speed transfers. |
| —-Removable Flash Media Boot Sequence | External DriveKeys First | Allows the host to boot from external USB keys (and iLO). Necessary for firmware updates, … |
| –Processor Options | | |
| —-No-Execute Memory Protection | Enabled | Needed for vSphere |
| —-Intel® Virtualization Technology | Enabled | Needed for vSphere |
| —-Intel® Hyperthreading Options | Enabled | Divides each core in 2 logical CPU's, improving the vSphere CPU schedulers possibilities. |
| —-Processor Core Disable | All Cores Enabled | No reason to disable cores. |
| —-Intel® Turbo Boost Technology | Enabled | When not all cores are used, ESX will park those cores and over clock the other ones. When an ESX host is not using all its cores, the active cores will run faster resulting in faster VM speeds. |
| —-Intel® VT-d | Enabled | Needed for vSphere (VMDirectIO, …) |
| –NUMLOCK Power-On State | Disabled | In most server rooms or when using a laptop to access the server console, a numeric keypad is not available. |
| Power Management Options | | |
| –HP Power Profile | Custom | Allows to enable custom Power settings specific for vSphere |
| –HP Power Regulator | OS Control Mode | Hands over the Power Management to vSphere. The other options give this control to the server itself. |
| –Redundant Power Supply Mode | High Efficiency Mode (Auto) | By default (Balanced Mode), the server uses all installed PSU's. This might look like the most efficient use, but the more power is drawn from a PSU, the more efficient it operates. The less power you draw from a PSU, the more gets lost to keep the PSU working. Thus, it is best to use the minimum amount of PSU's so they deliver the highest possible output. The remaining PSU's are placed in standby. This settings does not affect redundancy as the standby PSU's jump in as soon as an active one fails. By using the 'Auto' mode, the active PSU's are chosen based on the server's serial number (odd or even number = odd or even PSU numbers). This makes sure that all power circuits in the racks are evenly used. |
| –Advanced Power Management Options | | |
| —-Minimum Processor Idle Power State | C3 State | Needed for vSphere DPM. Allows vSphere to halt unneeded cores. |
| —-Maximum Memory Bus Frequency | Auto | Memory only runs at 1 speed in these servers -> 800 MHz |
| —-PCI Express Generation 2.0 Support | Auto | Server will detect PCIe Generation itself. Forcing it to PCIe 2.0 will make all PCIe 1.0 cards unusable. |
| —-Dynamic Power Savings Mode Response | Fast | Switch faster between processor states. |
| —-Collaborative Power Control | Enabled | Allows vSphere to control the PCC Interface |
| —-DIMM Idle Power Saving Mode | Enabled | DIMMs can put themselves into Low Power mode when not used. This will save some power if not all memory is used on the host. |
| Server Availability | | |
| –ASR Status | Disabled | ASR monitors an agent running in the Service Console. When this does not respond within 10 minutes, the host is rebooted. However, if the agent fails or the Service Console becomes sluggish (even though the VM's are perfectly fine), ASR will detect this as a system hang and will reboot the server. Furthermore, in case of a PSOD, ASR will reboot the server as well. This reboot might cause a loss of some logfiles. |
| –ASR Timeout | 10 Minutes | This has no effect since ASR is disabled. |
| –Thermal Shutdown | Enabled | To protect your server, it will be shutdown in case it gets too hot. |
| –Wake-On LAN | Enabled | vSphere DPM uses Wake-On LAN to power on servers (it uses iLO first, but falls back on Wake-On LAN) |
| –POST F1 Prompt | Disabled | The system boots if critical components fail. |
| –Power Button | Enabled | Power Button behaves like it should |
| –Automatic Power-On | Disabled | If set to enabled, the server will power-on as soon as AC Power is available. When set to disabled, power is restored to its previous state when AC Power is available. |
| –Power-On Delay | No Delay | When AC Power is restored, all systems will come online at the same time causing a power spike. If the power system is unable to handle this, a random delay will solve this problem. |
| BIOS Serial Console & EMS | | |
| –BIOS Serial Console Port | Auto | |
| –BIOS Serial Console Baud Rate | 9600 | |
| –EMS Console | Disabled | |
| –BIOS Interface Mode | Auto | |
| Advanced Options | | |
| –Advanced System ROM Options | | |
| —-Option ROM Loading Sequence | Load Embedded Devices First | Embedded devices should be loaded first so PXE boot from onboard NICs is always possible. |
| —-MPS Table Mode | Full Table APIC | vSphere needs this set to Full Table APIC |
| —-ROM Selection | Use Current ROM | Backup ROM is only needed when a firmware flash was unsuccessful. |
| —-NMI Debug Button | Enabled | Can be used to generate a NMI through the button on the system board. |
| —-Virtual Install Disk | Disabled | This Virtual Install Disk only contains drivers for Microsoft Windows Operating system. |
| —-PCI Bus Padding Options | Enabled | Disabling this option is only necessary for certain older expansion cards. |
| —-Power-On Logo | Enabled | Disabling has no improvements on boot-times. |
| –Video Options | Optional Video Primary, Embedded Video Disabled | Default setting. |
| –Power Supply Requirements Override | Default Power Supply Requirements | PSU requirements will be calculated depending on server power requirements. |
| –Thermal Configuration | Optimal Cooling | Fans will run at their minimum speed for adequate cooling. Saves some power since they don't run at full speed (less noise as well) |
| –Advanced Performance Tuning Options | | |
| —-HW Prefetcher | Enabled | In previous CPU generations, disabling this options gave better performance. With the Nahalem architecture, it does provide benefits (better caching) |
| —-Adjacent Sector Prefetch | Enabled | Similar to HW Prefetcher. |
| —-Hemisphere Mode | Auto | Hemisphere will be enabled if your memory configuration allows it (see HP QuickSpecs for optimal Hemisphere modes) |
| —-Node Interleaving | Disabled | Since vSphere utilizes NUMA nodes, there is no need to disable NUMA (= enable Node Interleaving) |
| –Drive Write Cache | Disabled | Only the DVD-ROM drive is attached to the onboard SATA controller. Writes are not possible to this device thus it can be left disabled. This setting has NO effect on the Smart Array Controller settings. |
| –Asset Tag Protection | Unlocked |
Ref: http://boerlowie.wordpress.com/2010/09/03/recommended-bios-setting-on-hp-proliant-dl580-g7-for-vsphere
Wednesday, April 27, 2011
Remote monitoring Sun Systems using ipmitool
The open-source tools ipmitool can be used to help manage and monitor Sun via the IPMI.
Chasis Status
# ipmitool -I lan -U root -H 192.168.1.5chassis status
Change Password
# ipmitool -I lanplus -H <IP Address> -U root -P <oldpassword> user set password 2 <newpassword>
Managing the System Event Log
Use ipmitool's sel elist command to print out the contents of the System Event Log
# ipmitool -I lan -H 192.168.1.5-U root sel elist
If the System Event Log contains a large number of entries, the last modifier can be used with the sel elist subcommand to show only a specific number of the most recent events.
# ipmitool -I lan -H 192.168.1.5-U root sel elist last 2
Clear the System Event Log
# ipmitool -I lan -H 192.168.1.5-U root sel clear
Use the led get command to display the state of the LED lights on a system
# ipmitool -I lan -H 192.168.1.5-U root sunoem led get
Use the sdr command to display sensor values
# ipmitool -I lan -H 192.168.1.5-U root sdr type voltage
Display the Service Processor's network configuration
# ipmitool -I lan -H 192.168.1.5-U root lan print 1
Print a list of all Field Replaceable Unit (FRU) inventory data
# ipmitool -I lan _H 192.168.1.5-U root fru print
Use the restart_cause command to display the cause of the last system restart
# ipmitool -I lan -H 192.168.1.5-U root chassis restart_cause
Perform a hard reset of a remote system
# ipmitool -I lan -H 192.168.1.5-U root chassis power reset
Request a PXE boot on the next reboot
# ipmitool -I lan -H 192.168.1.5-U root chassis bootdev pxe
Some more….
Run the following against the Ilom:
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> bmc info
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sel elist
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> fru
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sensor
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sunoem led get all
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sunoem sbled get all
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sdr elist
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sdr elist full
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sdr elist all
ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> chassis status
Monday, April 25, 2011
HP Hard drive LED alert combinations
Hot-plug SCSI hard drive LED combinations
SAS and SATA hard drive LED combinations
Monday, April 18, 2011
Sun 6000 Modular System - Identify the IP and MAC Addresses
You must know the CMM IP address to log into the CMM through the NET MGT port. You also must know the IP address of the service processor (SP) of any server module that you want to log into through the network.
Perform this task to identify the CMM IP addresses, such as when you want to log into the CMM through your network and the DHCP server assigned the IP address.
- Use one of the following methods to identify the CMM IP address:
-
Access the CMM ILOM though the SER MGT port.
- Connect a terminal device to the CMM SER MGT port.
- Log into the CMM though the CMM SER MGT port.
- View the CMM IP address and MAC address information:
-> show /CMM/network /CMM/network Targets: test Properties: commitpending = (Cannot show property) dhcp_server_ip = none ipaddress = 10.7.95.153 ipdiscovery = static ipgateway = 10.7.95.254 ipnetmask = 255.255.255.0 macaddress = 00:21:28:3E:2B:B6 pendingipaddress = 10.7.95.153 pendingipdiscovery = static pendingipgateway = 10.7.95.254 pendingipnetmask = 255.255.255.0 state = enabled switchconf = port0
- View the IP addresses or MAC address of server modules, using the ILOM show command with the path of each server module.
Replace the x in BLx with the number of the server module.
-> show /CH/BLx/SP/network /CH/BL0/SP/network Targets: Properties: type = Network Configuration commitpending = (Cannot show property) ipaddress = 10.7.95.155 ipdiscovery = static ipgateway = 10.7.95.254 ipnetmask = 255.255.255.0 macaddress = 00:21:28:14:F6:5B pendingipaddress = 10.7.95.155 pendingipdiscovery = static pendingipgateway = 10.7.95.254 pendingipnetmask = 255.255.255.0 state = enabled
-
On your DHCP server, review the IP address assignment information.
Sometimes you can obtain the IP address assignments by viewing the DHCP log files on the server. If you know the MAC address of the CMM or server module, you can locate the IP address assigned to it.
The CMM and server module MAC addresses are also listed on the Customer Information sheets that are included in a pouch on the outside of the shipping container.
-
Monday, December 13, 2010
How to inject SATA drivers (AHCI) after XP installation.
1) Copy bellow text to a notepad and change the file extension as ".reg" . Run it to change the registry entries.
2)Download Intel Matrix Storage Manager-Package for your make and model and extract its files by running using the following switches "-a –a"
3) Copy "iastor.sys " from freshly extracted folder to %Windows%\System32\Drivers\
4) Rrestart your computer, enter the BIOS and switch back to Advanced, AHCI-mode.
5) Save, exit and load Windows XP from your HD (it should now start properly).
6) When XP goes for the SATA driver-installation procedure, stop it and run Matrix Storage Manage setup from the previously extracted folder to complete the SATA installation
7) Restart your system.
Done
======================================================
; --
; traegt einige Betriebsmodi der SATA-AHCI-Hostadapter
; der I/O Controller Hubs
; ICH7R, ICH7-DH, ICH7M-DH
; ICH8R, ICH8-DH, ICH8-DO, ICH8-M, ICH8-ME
; ICH9, ICH9R, ICH9-DH, ICH9-DO
; ICH9-M, ICH9-ME (experimentell)
: ICH10, ICH10R
; der Intel-Chipsaetze
; 955X, 945P, 945G, P965, G965, Q965, Q963
; 945GM, 945PM, 965GM, 965PM
; G31, G33, G35, P31, P35, X38, X48
; G43, G45, P43, P45
; GM45, GM47, PM45
; Q45, P55 (experimentell)
; in die Registry einer Windows-XP-Installation ein
; (XP Home, Professional, x64 Professional Edition).
; --
; Der Treiber IaStor.sys muss man manuell kopieren
; in das Verzeichnis
; %SYSTEMROOT%\system32\drivers\iaStor.sys
; Weitere Tipps: c't 23/05, S. 210
; und
; SATA-AHCI-Treiber nachrüsten:
;
; Weitere Informationen:
; ICH7R: www.intel.com/design/chipsets/datashts/307013.htm
; IaStor.sys:
; Enthalten in Intel Matrix Storage Manager (IMSM), 32- und 64-Bit:
; http://support.intel.com/support/chipsets/imsm/
; Trademarks: Intel (www.intel.com), Microsoft (www.microsoft.com)
; ICH7 AHCI
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_27c1]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH7-M AHCI
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_27c5]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH7 RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_27c3]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH7-M DH RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_27c6]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH8, ICH8R, ICH8-DO, ICH8-DH AHCI 6-Port
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2821]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH8, ICH8R, ICH8-DO, ICH8-DH AHCI 4-Port
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2824]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH8, ICH8R, ICH8-DO, ICH8-DH RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2822]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH8-M, ICH8-ME AHCI
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2829]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH8-M RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_282A]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9, ICH9R, ICH9-DO, ICH9-DH AHCI Ports 0-5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2922]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9, ICH9R, ICH9-DO, ICH9-DH AHCI Ports 0, 1, 4, 5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2923]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9R RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2822]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9R RAID Alternativ je nach Bit 7 im Register D21:F2:9Ch (siehe Datenblatt)
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2925]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9-M, ICH9-ME AHCI
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2929]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9-M RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_282A]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH9-M RAID Alternativ je nach Bit 7 im Register D21:F2:9Ch (siehe Datenblatt)
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_292C]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH10, ICH10R AHCI Ports 0-5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3A22]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH10R RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3A25]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH10DO AHCI
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3A02]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; ICH10DO RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3A05]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; P55 AHCI Port 0-5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3B22]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; P55 AHCI Port 0,1,4,5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3B23]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; P55 RAID ist 3A25 wie ICH10R
; P55 Mobile AHCI Port 0-5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3B2F]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; P55 Mobile AHCI Port 0,1,4,5
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3B29]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
; P55 Mobile RAID
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_3B2C]
"Service"="iaStor"
"ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}"
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\iaStor]
"Type"=dword:00000001
"Start"=dword:00000000
"Group"="SCSI miniport"
"ErrorControl"=dword:00000001
"ImagePath"="system32\\drivers\\iaStor.sys"
"tag"=dword:00000019
"DisplayName"="Intel AHCI Controller"
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\iaStor\Parameters]
"AtapiOnPrimary"=dword:ffffffff
"AtapiOnSecondary"=dword:ffffffff
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\iaStor\Enum]
=====================================================================
Thursday, November 18, 2010
Intel Matrix Storage driver Windows XP and STOP: 0x0000007B - SCCM OSD
Drop down box on the Apply Driver Package TS action only allows you to select drivers where Class=SCSIAdapter. The AHCI drivers you're talking about in this thread have Class=hdc by default.
Follow the bellow steps to get the AHCI drivers to work:
1. Delete the nonfunctional Intel AHCI & RAID Controller drivers from my Drivers list in SCCM
2. Extract the downloaded mass storage drivers to a temp directory
3. Edit the iaahci.inf file by changing the line that says Class=hdc to instead say Class=SCSIAdapter
4. Import the driver into SCCM, add to the appropriate driver package and update my DP
5. Edit my Apply Driver Package TS to select the appropriate AHCI driver
Wednesday, April 28, 2010
Unknown Device Identifier
Download Page: http://www.zhangduo.com/udi.html
Saturday, January 10, 2009
How to clear an unknown BIOS password.
On the computer motherboard locate the BIOS clear / password jumper or dipswitch and change its position. Once this jumper has been changed, turn on the computer and the password should be cleared. Once cleared, turn the computer off and return the jumper or dipswitch to its original position
For more reference click here